Explanation
An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please check error logs for the presence of additional downstream device error data. Critical IOH-PCI Error
Severity
Error
User response
Complete the following steps:
- Check IBM support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.
- Check log for a separate error for an associated PCIe device and service that error.
- (Trained service technician only) Replace Processor. Inspect Processor socket for foreign debris or damage. If debris is found, remove debris. If socket is damaged, replace the system board first.