Explanation

An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please check error logs for the presence of additional downstream device error data. Critical IOH-PCI Error

Severity

Error

User response

Complete the following steps:
  1. Check IBM support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.
  2. Check log for a separate error for an associated PCIe device and service that error.
  3. (Trained service technician only) Replace Processor. Inspect Processor socket for foreign debris or damage. If debris is found, remove debris. If socket is damaged, replace the system board first.
  4. (Trained Service technician only) If error recurs, replace the system board.