An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Explanation
An over temperature condition for memory has been detected.
May also be shown as
806f0a0c2009ffff or 0x806f0a0c2009ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
CIM Information
Prefix: PLAT and ID:
0146
SNMP Trap ID
0
Automatically notify Support
No
User response
Complete the following steps:
- Check the CMM or FSM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Make sure that the DIMM baffles are in place.
- If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.