Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation
The I/O expansion adapter in I/O expansion connector 1 has reported a fault.
May also be shown as
800702172c01ffff or 0x800702172c01ffff
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
CIM Information
Prefix: PLAT and ID:
0522
SNMP Trap ID
50
Automatically notify Support
No
User response
Complete the following steps:
- Remove any recently installed components.
- Try to power on the chassis.
- If the chassis successfully powers on, complete the following steps:
- Check the ServerProven website
to make sure that recently installed components are compatible with the chassis.
- Inspect the previously installed components for physical damage.
- If the chassis does not successfully power on or if this is not the first occurrence of
this problem, replace the I/O expansion adapter.