40000022-00000000
SSL data in the Management Controller [arg1] configuration data is invalid. Clearing configuration data region and disabling SSL.

Explanation

There is a problem with the certificate that has been imported into the IMM. The imported certificate must contain a public key that corresponds to the key pair that was previously generated through the "Generate a New Key and Certificate Signing Request " link.

May also be shown as 4000002200000000 or 0x4000002200000000

Severity

Error

Alert Category

System - other

Serviceable

No

CIM Information

Prefix: IMM and ID: 0034

SNMP Trap ID

22

Automatically notify Support

No

User response

Complete the following steps until the problem is solved:
  1. Make sure that the certificate that you are importing is correct.
  2. Try to import the certificate again.