Explanation
IMM Indicates failure in the 9545A bus (BUS 7).
Severity
Error
Serviceable
Yes
Recoverable
No
Automatically notify Support
No
User response
Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.