(Trained service technician only) Use these instructions
to install a replacement rear LED card in the chassis midplane.
To install the rear LED card in the midplane, complete
the following steps.
- Insert the rear LED card into the connector on the midplane.
- Connect the cable to the rear LED card.
- Replace the T-10 Torx screw that you removed earlier to
secure the rear LED card.
Important: After you install
the rear LED card that comes with a new midplane, you must reassemble
the chassis and program the vital product data (VPD) that is stored
on the card, so that Lenovo XClarity Administrator can
use the same UUID for the chassis afterwards.
Complete the following
steps:
- Reinstall the shuttle into the chassis (see Replacing the shuttle).
- Reinstall all of the components and component bay fillers that
you removed from the rear of the chassis. See the following tasks
for additional instructions:
- Connect any cables that you disconnected from the modules in the
rear of the chassis.
- Connect the chassis to power (see Connecting the chassis to power).
- Log in to the CMM and
access the command-line interface (CLI). You can access the CMM CLI
through a direct serial or Ethernet connection to the CMM,
through a Telnet connection to the IP address of the CMM,
or through a Secure Shell (SSH) connection to the CMM.
You must authenticate with the CMM before
issuing commands. Use the CLI vpdrep command to program the
serial number, machine type model, and the universal unique identifier
(UUID) into the replacement rear LED card. The CLI command to program
this data can be executed in two ways, the data for the three command
arguments can be entered individually or together in any combination.
At least one command argument must be present. For example, to program
all three fields at once: vpdrep -sn -tm -uuid where:
vpdrep command arguments |
Description |
-sn |
Chassis serial number (7 alphanumeric characters) |
-tm |
Machine type model (7 alphanumeric characters) |
-uuid |
Universally unique identifier (32 hex digits,
spaces not allowed) |
- Restart the CMM for
the vital product data change to take effect. The vital product data
values can be queried by using the CLI info command.
- Close the release handles on the compute nodes and
I/O modules in order to seat the nodes and I/O modules in the midplane
connectors.
- Restart any compute nodes that
you shut down. See the documentation that comes with the compute node
for detailed instructions.
- The I/O Modules are powered-on automatically by the CMM.