Use these instructions to remove a 2-bay compute node from
the Flex System Carrier-Grade
chassis.
Attention: To maintain proper system cooling,
do not operate the chassis without a compute node or compute node filler
installed in each node bay. Install a compute node or
filler within 1 minute of the removal of a compute node.
Before
you remove a 2-bay
compute node, complete
the following tasks:
- Remove the airborne contaminant filter assembly bezel (see Removing the airborne contaminant filter assembly).
Note: Remove
only the airborne contaminant filter assembly bezel. You do not need
to remove the filter assembly mounting brackets in order to remove
a compute node.
- Make a note of the bay number. Reinstalling a compute node into
a different bay from the one from which it was removed can have unintended
consequences. Some configuration information and update options are
established according to bay number.
- Shut down the compute node operating
system; then, shut down the compute node. See
the documentation that comes with your compute node for
the procedure to shut down the operating system. Compute node documentation
is available from the Flex System compute nodes information page.
To remove a 2-bay compute node, complete
the following steps:
- Open the release handles (rotate the left handle to the
left and rotate the right handle to the right) to disengage the compute node from
the chassis.
- Slide the compute node out
of the node bay.
If you are not immediately replacing the compute node, complete
the following steps:
- Install a chassis shelf in the empty node bays (see Replacing a chassis shelf).
- Install a node bay filler in each empty bay.
- Reinstall the airborne contaminant filter assembly bezel (see Replacing the airborne contaminant filter assembly.
.