35010B08 : System-management processor firmware on [arg1] does not support the certificate cryptography algorithm configured on the CMM.

System-management processor firmware on [arg1] does not support the certificate cryptography algorithm configured on the CMM.

Severity

Warning

Alert Category

Nodes (Warning)

Log Source

Node_08

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0753

SNMP Trap ID

mmTrapBladeN

Automatically Notify Support

No

User Response

Ensure that the node system-management processor has the correct level of firmware to support the security functions enabled on the Chassis Management Module. If you cannot log onto the node system-management processor, you might need to temporarily set the certificate cryptography algorithm to the "RSA2048-SHA1" setting on the CMM