CMM local authentication server will not use imported certificate until firmware on node [arg1] is updated to a version that supports imported certificates.
Alert Category
Nodes (Informational)
Chassis LED that is Lit
None
CIM Information
Prefix:CMM
and ID:0798
Automatically Notify Support
No
User Response
Ensure that the node system-management processor has the correct level of firmware to support the security functions
enabled on the CMM. The CMM will begin using the imported server certificate for the local authentication server
after the system-management processor firmware levels for all nodes in the chassis have been updated,
and the imported server certificate is re-applied via the CMM web UI:
- From the CMM web-based user interface, click Mgt Module Management->Security->SSL Server Certificate.
- Select Re-Apply Installed Certificate.