00015803 : Chassis Management Module cannot convert the host name [arg1] to IP for syslog collector [arg2].

Chassis Management Module cannot convert the host name [arg1] to IP for syslog collector [arg2].

The Chassis Management Module (CMM) cannot resolve the specified host name for the specified syslog collector.

Severity

Informational

Alert Category

Chassis/System Management (Informational)

Log Source

SERVPROC

Serviceable

Yes

Recoverable

No

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0458

SNMP Trap ID

mmTrapChassisS

Automatically Notify Support

No

User Response

Complete the following steps until the problem is solved:
  1. Make sure that the syslog collector is configured correctly and can be reached from the CMM.
  2. Make sure that the Domain Name System (DNS) is configured correctly for host name resolution.