806f060d-0400ffff : Array [ComputerSystemElementName] has failed. (Drive 0)

Array [ComputerSystemElementName] has failed. (Drive 0)

Severity

Error

Alert Category

Critical - Hard Disk drive

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0176

SNMP Trap ID

5

Automatically Notify Support

Yes

User Response

  1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
  2. Make sure that the SAS cable is connected correctly.
  3. Replace the SAS cable.
  4. Replace the RAID adapter.
  5. Replace the hard disk drive that is indicated by a lit status LED.