Invalid or Unsupported firmware or software was detected on system [ComputerSystemElementName]. (IMM2 FW Failover)
Alert Category
Critical - Other
CIM Information
Prefix:PLAT
and ID:0446
Automatically Notify Support
No
User Response
- Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
- Recover the server firmware from the backup page by restarting the server.
- Update the server firmware to the latest level (see Updating the firmware).
Important: Some cluster solutions require specific code levels or coordinated code updates.
If the device is part of a cluster solution, verify that the latest level of code is supported for
the cluster solution before you update the code.
- Remove components one at a time, restarting the server each time, to see if the problem goes away.
- If the problem remains, (trained service technician) replace the system board.