Single node does not power on |
- Check the event logs for any events that are related to the compute
node, and solve them. If a management node is available, check the
event log on the management node. Otherwise, the Chassis Management Module event
log.
- Make sure that the CMM can
recognize the compute node. Log in to the CMM user
interface and verify that the compute node appears in the chassis
view. If the CMM cannot
recognize the compute node, remove the compute node and inspect the
compute node and the back of the node bay to make sure that there
is no physical damage to the connectors.
- Make sure that the power policy that is implemented on the CMM is
sufficient to enable the compute node to power on. You can view the
power policy from the CMM user
interface (click Power Management > Power Modules and
Management).
- Make sure that the management node has completed the discovery
of the compute node. Log in to the management node user interface
and verify that the compute node appears in the list of manageable
systems.
- Replace the compute node.
Note: Until you are able to replace
the compute node, you can attempt to power on the compute node from
the CMM or
from the management node user interface.
|
Multiple nodes do not power on |
Check the event logs for any events
that are related to the compute nodes, and solve them. If a management
node is available, check the event log on the management node. Otherwise,
check the Chassis Management Module event
log.
|
Compute node does not power off |
- Attempt to power off the compute node through the management node
user interface, if a management node is available. Otherwise, attempt
to power off the compute node through the CMM user
interface.
- Attempt to restart the system-management processor for the compute
node. You can restart the system-management processor through the CMM user
interface. Click the compute node in the chassis view and then click Restart
System Mgmt Processor. After the system-management processor has
been restarted, attempt to power off the compute node from the CMM.
- Attempt to power off the compute node by using the power button
on the front of the node.
- Attempt to reset the compute node from the CMM command-line
interface (CLI) by using the reset command.
- Reseat the CMM;