Device Periscope 2 has been removed from unit [PhysicalPackageElementName].
Alert Category
System - Other
CIM Information
Prefix:PLAT
and ID:0537
Automatically Notify Support
No
User Response
Informational message.
On a LOM model compute node, if you are utilizing LOM and it is not working ensure you have the necessary fabric connector installed.
- To utilize the LOM:
- have the LOM model compute node
- have the corresponding fabric connector installed
- Information regarding the fabric connectors:
- LOM 1 utilizes the fabric connector in location 1.
- LOM 2 utilizes the fabric connector in location 2.
- I/O expansion adaptor in I/O expansion slot 1 and the fabric connector in slot 1 utilize the same connector and only one of the two can be installed at a time.