Use the information in this section to troubleshoot multiple
nodes that cannot ping the Flex System Manager management
node in a different chassis on the data network.
Complete the following steps until the problem is solved:
- Make sure that the management node is powered on and is not hung,
by logging in to the management node. If you are unable to log in
from the management network, attempt to log in from the data network.
If the management node is powered on and hung, perform a virtual reseat
of the management node from the Chassis Management Module.
- Make sure that the I/O module is powered on and is not hung, by
pinging the I/O module from the management node. If the I/O module
is powered on and hung, reset the I/O module. Make sure that the correct
ports are enabled for the node on the I/O module.
- Make sure that the management network port (eth1) in the management
node is enabled. Make sure that the port configuration settings are
correct for the data network.
- Make sure that the configuration settings for each node are correct
and that the data network ports are enabled.
- Make sure that the configuration settings in the I/O module are
correct and that the applicable ports are enabled for your compute
nodes and the management node on the I/O module. If the problem remains,
complete the following steps:
- Restart the I/O module.
- Check the Lenovo Support Portal for any firmware
updates that might apply to this issue. You can view the release notes
for a firmware update to determine the issues that are addressed by
the update.
- Perform a virtual reseat of the I/O module.
- Replace the I/O module.
- Check the Lenovo Support Portal for any service
bulletins that are related to network connectivity.
- Remove the management node and make sure that the connectors on
the chassis midplane and the node are not damaged.
- (Trained service technician only) Complete the following steps:
- Force the link/duplex speed.
- Check the connectors on the nodes and the chassis midplane to
make sure that no pins are bent.
- Replace the I/O expansion card in the management node.