Complete the following steps until the problem is solved.
- Attempt to power off the compute node through the management node
user interface, if a management node is available. Otherwise, attempt
to power off the compute node through the Chassis Management Module user
interface.
- Attempt to restart the system-management processor for the compute
node. You can restart the system-management processor through the Chassis Management Module user
interface. Click the compute node in the chassis view and then click Restart
System Mgmt Processor. After the system-management processor has
been restarted, attempt to power off the compute node from the Chassis Management Module.
- Attempt to power off the compute node by using the power button
on the front of the node.
- Attempt to reset the compute node from the Chassis Management Module command-line
interface (CLI) by using the reset command.
- Reseat the Chassis Management Module;
then, perform steps 1-5 again.