(IBM Flex System devices only) The following topic provides
information about the pNIC virtual mode.
About this task
In pNIC virtual mode the
IBM Flex System CN4022 2-Port Adapter shows the physical characteristics
of the adapter through the uEFI utility. The adapter contains two
physical ports with the Ethernet, iSCSI offload and FCoE offload personalities
automatically enabled. Each port has one MAC (Ethernet) address, one
MAC (iSCSI) address, and one WWN (Fibre Channel) address. The MAC
addresses have factory default values that can be changed.
Procedure
To configure the IBM Flex System
CN4022 2-Port Adapter for use in
IFM using the
pNIC virtualization mode, complete the following steps:
- From the uEFI utility, select and select the port to
configure.
- Select the pNIC virtualization mode from the Main Configuration
Page.
The Permanent MAC Address is the same for each port.
After IFM is
applied, the Virtual MAC Address is different for each port
and is used by the adapter and the device drivers in the OS.
- Use the information in Profiles to apply an IFM pattern to
the IBM Flex System CN4022 2-Port Adapter.
What to do next
Optionally, you can verify
the configuration of the adapter through the uEFI utility, IFM, and the CMM
CLI mode.
- Verify that the adapter uses the new addresses from the IFM configuration.
The compute node has a new virtual MAC address on the Main Configuration
Page.
- Verify that IFM reflects
the address consumption. The adapter is inserted in Mezz 2, and has
2 ports. Both Port 1 and Port 2 have Normal status, which means the
ports consumed the new addresses.
- To verify Fibre Channel consumption from the uEFI utility, go
to the Main Configuration Page for the port. To verify Fibre Channel
consumption through IFM,
see Hardware devices.
- You can verify the address consumption through the CMM CLI mode.