Use these instructions to remove a Flex System
Chassis Management Module from
the Flex System Enterprise
Chassis.
Note: These instructions assume that the chassis is connected
to power.
Before you remove a
CMM,
complete the following steps.
Important: If you have just
installed a standby CMM in
the chassis, do not remove the primary CMM until
the Active LED on the standby CMM is
lit (indicating that the standby CMM is
controlling the chassis). The standby CMM requires
about 2 minutes to become active and receive initial status information
and firmware from the primary CMM.
- If the CMM that
you are replacing is the only CMM in
the chassis and the CMM is
functioning, save the configuration file before you proceed.
- In the CMM web
interface, configurations are saved in the Manage Configuration page
(select Configuration from the Mgt Module Management menu).
All fields and options are described in the CMM web
interface online help.
- You can also use the write command in the CMM command-line
interface (CLI). See write command for information about commands.
- If you are removing the primary CMM in
the chassis, stop all CMM local
and remote sessions before you proceed, to avoid an unexpected termination
of sessions.
- Remove any external devices that block access to the rear of the
chassis.
- Disconnect all cables from the CMM.
To remove the CMM,
complete the following steps.
- Press the release latch down and rotate the handle down
until it stops, to disengage the CMM from
the chassis.
- Slide the CMM out
of the chassis and place it on a flat, static-protective surface.
Note: If the chassis has only one CMM and
you remove the CMM,
the fan modules will automatically accelerate to full speed. The fan
modules will continue to run at full speed until the CMM is
replaced.