Use these instructions to prepare your CMM for
redundant operation.
To prepare your CMM for
redundancy, complete the following steps:
- Install the standby CMM in
the available CMM bay.
- Wait approximately 2 minutes while the primary CMM transfers
firmware and configuration information to the standby CMM.
Note:
- Whenever power is restored to an Flex System Enterprise
Chassis that
has two functional CMMs,
the CMM in CMM bay
1 is typically prioritized as the primary CMM,
even if the CMM in CMM bay
2 was the primary CMM before
power was removed, however, sometimes the CMM in
bay 2 will be prioritized, making it the primary CMM.
- For the most recent version of the optional Flex System Manager management
software, which you can use to manage an Flex System Enterprise
Chassis with
a redundant CMM,
go to Lenovo Data Center Support site.
- Configure CMM failover
response: