You must configure the CMM to use the command-line interface.
You configure only the primary (active) CMM. If a standby (redundant) CMM is installed, it receives the configuration and status information automatically from the primary CMM when necessary. The configuration information in this topic applies to the primary CMM, which might be the only CMM in the Flex System Enterprise Chassis.
If the CMM that you are installing is the only CMM in the Flex System Enterprise Chassis and you have a saved CMM configuration file, you can apply the saved configuration file to the replacement CMM. See read command for information about applying a saved configuration file.
For the primary CMM to communicate, you must configure the IP address for the remote management and console (Ethernet) port (eth0) of the CMM by using the CMM CLI ifconfig -eth0 command (see ifconfig command for information about command use). The initial automatic CMM configuration enables a remote console to connect to the CMM to configure the port completely and to configure the rest of the Flex System Enterprise Chassis.
After you connect the primary CMM to the network, the Ethernet management port connection is configured in one of the following ways. Either of these actions enables the Ethernet management port on the primary CMM.
To configure the CMM Ethernet ports, complete the following steps: