This topic lists error messages for the clear command.
See Common errors for a list of error messages that apply to all commands. See clear command for information about command syntax and examples of command use.
Error message | Definition |
---|---|
Disabling failover failed | An error occurs while disabling failover. |
Firmware update is in progress. Try again later. | The user tries to reset the CMM to its default configuration during a firmware update. The error message displays and the CMM configuration does not reset. |
Internal error resetting to defaults. | An error occurs while the CMM is resetting the CMM to its default configuration. The error message displays and the CMM configuration does not reset. |
Not supported by this type of I/O module. Type env -h for help on changing targets | A user tries to run a command option on an I/O module that does not support it. |
This command cannot be issued right now. If you still want to clear the primary CMM, please use 'clear -cnfg -o' to override this warning. | A condition exists that is preventing the CMM from being cleared. You can either wait and try the command again or force the CMM to clear immediately using the clear -cnfg -o override option. |
This command cannot be issued right now. The standby CMM is in an unknown state, and a reset might result in a failover. If you still want to clear the primary CMM, please use 'clear -cnfg -o' to override this warning. | A condition exists that is preventing the CMM from being cleared. You can either wait and try the command again or force the CMM to clear immediately using the clear -cnfg -o override option. |
This command cannot be issued right now. The primary CMM is verifying the code level on the standby CMM. Please try again later. | A user tries to issue a command to the CMM when it is unavailable. |
This command cannot be issued right now. The standby CMM is flashing, and resetting the primary CMM to defaults might result in a failover. Please try again later. | A user tries to reset the primary CMM to defaults while the standby CMM is unable to support failover. |
This command cannot be issued right now. The standby CMM is in a post-flash initialization state, and resetting the primary CMM to defaults might result in a failover. If you still want to reset the primary CMM, please use 'clear -cnfg -o' to override this warning. | A user tries to reset the primary CMM to defaults while the standby CMM is unable to support failover. |
This command cannot be issued right now. The primary CMM is initializing, and a reset might result in a failover. If you still want to clear the primary CMM, please use 'clear -cnfg -o' to override this warning. | A condition exists that is preventing the CMM from being cleared. You can either wait and try the command again or force the CMM to clear immediately using the clear -cnfg -o override option. |