This command displays Flex System Enterprise Chassis cooling zone and fan module health information.
If command syntax is not correctly entered, or if a command fails to run, an error message is returned. See Common errors for a list of error messages that apply to all commands or coolingzones command errors for a list of error messages that are specific to the coolingzones command.
Function | What it does | Command | Target (see paths in Command targets) |
---|---|---|---|
Display cooling zone information | Display information for all cooling zones in the Flex System Enterprise Chassis. | coolingzones | Flex System Enterprise
Chassis:
|
Display specific cooling zone information | Displays detailed information for the specified cooling zone. | coolingzones
z zone where zone is the cooling zone index number to display. Valid cooling zone index numbers can be seen by running the coolingzones command with no argument. |
Flex System Enterprise
Chassis:
|
coolingzones
coolingzones z2
The following example shows the information that is returned from these commands:
system> coolingzones Zone 1: ------- Status: ok Provider(s): blower[1] blower[2] blower[3] blower[4] Receiver(s): blade[5],blade[11] Zone 2: ------- Status: warning Provider(s): blower[6] not present blower[7] blower[8] blower[9] Receiver(s): blade[4] Zone 3: ------- Status: warning Provider(s): blower[5] not present Receiver(s): mm[1] switch[2] Zone 4: ------- Status: ok Provider(s): blower[10] Receiver(s): switch[1],switch[3] system> coolingzones z2 Status: warning Cooling Provider(s): -------------------- blower[6]: not present blower[7]: Status: ok Count: 1 Speed: 38% Avg RPM: 4352 Controller State: Operational blower[8]: Status: ok Count: 1 Speed: 38% Avg RPM: 4352 Controller State: Operational blower[9]: Status: ok Count: 1 Speed: 38% Avg RPM: 4416 Controller State: Operational Cooling Receiver(s): -------------------- blade[4] system>