Use this information to install a management node in a Flex System Enterprise Chassis.
Before you begin
Before you install the management node in a chassis, read
Safety and
Installation guidelines.
Statement 21
CAUTION:
Hazardous energy is present when the node is connected
to the power source. Always replace the node cover before installing
the compute node.
Procedure
To install the management node in a chassis, complete
the following steps.
Note: If the management node is connected to an
I/O expansion unit, see the documentation that came with the I/O expansion
unit for instructions for installing the management node in the chassis.
- Select the node bay.
Notes: - If you are reinstalling a management node that you removed, you
must install it in the same node bay from which you removed it. Reinstalling
a management node into a different node bay can have unintended consequences.
If you reinstall the management node into a different node bay, you
might have to reconfigure the management node.
- To maintain proper system cooling, do not operate the Flex System Enterprise Chassis without
a management node, I/O expansion unit, or node bay filler in each
node bay.
- Make sure that the front handle on the management node
is in the open position.
- Slide the management node into the node bay until it stops.
- Push the front handle on the front of the management node
to the closed position.
Note: After the management node
is installed, the IMM2 in the management node initializes and synchronizes
with the chassis management module. This process takes approximately
90 seconds to complete. The power LED flashes rapidly, and the power
button on the management node does not respond until this process
is complete.
- Turn on the management node (see Turning on the management node for instructions).
- Make sure that the power LED on the management node control
panel is lit continuously, indicating that the management node is
receiving power and is turned on.
- You can place identifying information on the
label tabs that are accessible from the front of the compute node.
What to do next
If this is the initial installation of the management
node in the chassis, you must set up the IBM® Flex
System Manager management software according
to the procedure described in Initial setup.