This command resets a compute node, compute node system-management processor, I/O module, or the primary or standby CMM.
If command syntax is not correctly entered, or if a command fails to run, an error message is returned. See Common errors for a list of error messages that apply to all commands or service command errors for a list of error messages that are specific to the service command.
Function | What it does | Command | Target (see paths in Command targets) |
---|---|---|---|
Virtual reseat | Performs a virtual reseat (service-level reset)
of the specified command target. A virtual reseat simulates physical removal and insertion of the command target. The virtual reseat removes standby power from the command target and then restores it. Each command target type has unique behavior when virtually reseated:
Attention:
Important:
(continued on next page) |
service
-vr This command can only be run by users who have
one or more of the following command authorities:
|
Primary or standby CMM:
Compute node or
storage node:
I/O module:
|
Virtual reseat (continued) |
Note: Do not perform a virtual reseat on a compute node that
indicates it is in maintenance mode. Indications of maintenance mode
are shown in the CMM or
IMM event logs and by management devices such as the
optional Lenovo XClarity Administrator.
|
||
Virtual reseat of primary CMM (suppress warnings for standby CMM) | Performs a virtual reseat (service-level reset)
of the specified command target. A virtual reseat simulates physical removal and insertion of the command target. The virtual reseat removes standby power from the command target and then restores it.
Attention:
|
service -vr -o This
command can only be run by users who have one or more of the following
command authorities:
|
Primary or standby CMM:
|
Hard restart | Performs a hardware reset of the system-management
processor of the specified command target. A hard restart directly
resets the system-management processor on the command target. The
power state of the command target is not affected by this reset. Note:
|
service
-hard This command can only be run by users who have
one or more of the following command authorities:
|
Compute node system-management
processor:
|
Example:
The following example shows the information that is returned from these commands: