Removing the hard disk drive cage

Use this information to remove the hard disk drive cage.

Before you remove the hard disk drive cage, complete the following steps:
  1. Read Safety and Installation guidelines.
  2. If the compute node is installed in an Flex System chassis, remove it (see Removing a compute node from a chassis for instructions).
  3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.

To remove the hard disk drive cage, complete the following steps.


Graphic illustrating removing a hard disk drive cage

  1. Remove the cover (see Removing the compute node cover).
  2. Remove the hot-swap hard disk drives and hard disk drive bay fillers (see Removing a hot-swap hard disk drive).
  3. Remove the hard disk drive backplane (see Removing the hard disk drive backplane).
  4. Using a T8 torx screwdriver, remove the four screws from the cage and rotate the cage from under the bezel; then, remove the cage from the compute node at an angle.
If you are instructed to return the hard disk drive cage, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.